CVE-2025-60963
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedOS Command Injection vulnerability in EndRun Technologies Sonoma D12 Network Time Server (GPS) F/W 6010-0071-000 Ver 4.00 allows attackers to execute arbitrary code, cause a denial of service, gain escalated privileges, and gain sensitive information.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceOS Command Injection vulnerability in EndRun Technologies Sonoma D12 Network Time Server firmware version 6010-0071-000 Ver 4.00 allows authenticated attackers (or unauthenticated depending on attack vector) to inject OS commands through the application's input fields, potentially leading to arbitrary code execution, denial of service, privilege escalation, and information disclosure. The high CVSS score (8.2) reflects the severe impact of successful exploitation.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 6010-0071-000CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- Low
- Integrity
- High
- Availability
- None
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device modelLog into the device web interface or check physical labeling to confirm the device is an EndRun Technologies Sonoma D12 Network Time ServerAffected if Device is NOT an EndRun Sonoma D12 model - this CVE does not apply to other models
-
Check the firmware versionNavigate to the device status or system information page in the web management interface, or use SNMP/CLI to query the firmware version stringAffected if Firmware version is exactly 6010-0071-000 Ver 4.00 - only this specific version is listed as affected
-
Verify remote management accessCheck the device network settings page to see if remote management/web administration is enabled and accessible from non-local networksAffected if Remote management interface is exposed to untrusted networks - the vulnerability can be exploited remotely in this configuration
-
Review authentication settingsCheck if default credentials are in use or if weak administrator accounts exist on the deviceAffected if Default or weak admin credentials are configured - authenticated exploitation is easier with these
-
Inspect for indicators of compromiseCheck for unexpected files in /tmp or /var directories via CLI access, review system logs for suspicious command patterns, look for new user accounts or cron jobsAffected if Unexpected files, suspicious log entries, or unauthorized configuration changes are found
You are affected if you are running the Sonoma D12 with firmware version 6010-0071-000 and the device management interface is network-accessible.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor firmware update/patch when available; until then, restrict network access to the device management interface using firewall rules or network segmentation, disable remote management if not required, and monitor for indicators of compromise.
- Consultation8.0 h
- Implementation4.0 h
- Testing6.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $6,304.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-60963 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-60963 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data