Sonoma D12 FirmwareOperating system · Endruntechnologies

CVE-2025-60965

CRITICAL · 9.1 CVSS v3.1 Published 2025-10-06
Mitigation only
No fix yet — a mitigation exists. There is no fixed release. A documented workaround reduces exposure in the meantime.
See remediation →
97/100
Remediation priority · Urgent
Remotely reachable Zero-click

Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.

NVD · unedited
OS Command Injection vulnerability in EndRun Technologies Sonoma D12 Network Time Server (GPS) F/W 6010-0071-000 Ver 4.00 allows attackers to execute arbitrary code, cause a denial of service, gain escalated privileges, gain sensitive information, and possibly other unspecified impacts.

Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.

dbcve analysis · moderate confidence

OS Command Injection vulnerability in EndRun Technologies Sonoma D12 Network Time Server firmware 6010-0071-000 Ver 4.00 allows unauthenticated attackers to inject malicious operating system commands through insufficient input sanitization, leading to arbitrary code execution, privilege escalation, denial of service, and potential information disclosure.

MitigationApply vendor firmware patch when available; prior to patch, restrict network access to the device management interface and disable unauthenticated management protocols if feasible.

Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.

Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.

NVD · CPE data
Sonoma D12 FirmwareOperating system
Affected:= 6010-0071-000

CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.

From the vector
Attack vector
Network
Complexity
Low
Privileges
High
User interaction
None
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.

dbcve checks

Work through these to decide whether this CVE applies to you.

  1. Identify the device model
    Access the device web interface or CLI and confirm the device is an EndRun Technologies Sonoma D12 Network Time Server. Check the system information page or device label for the model number.
    Affected if The device model is Sonoma D12 and it is running the affected firmware version.
  2. Check the installed firmware version
    Locate the firmware version in the device management interface (typically under System > Info, Status, or About). Verify if the version matches 6010-0071-000 Ver 4.00. If the device has a CLI, use commands like 'show version' or 'system info' to retrieve the firmware version.
    Affected if The installed firmware version is exactly 6010-0071-000 Ver 4.00.
  3. Verify network exposure of management interface
    Determine if the device management interface (web UI, CLI, or API) is accessible from untrusted networks. Check router/firewall rules and the device IP configuration. Attempt to access the device login page from an external network if permitted by policy.
    Affected if The management interface is exposed to unauthenticated or untrusted network access.
  4. Check for unauthenticated management protocols
    Review the device configuration for enabled management protocols such as HTTP, Telnet, or other unauthenticated access methods. Look for settings that allow unauthenticated command execution or API endpoints.
    Affected if Unauthenticated management protocols or interfaces are enabled and accessible.

You are affected if your Sonoma D12 device is running firmware version 6010-0071-000 Ver 4.00 AND the management interface is network-accessible to unauthenticated attackers.

Generated from the published advisory. Verify against your own configuration.

Check your environment

Paste your version and any relevant configuration and it will be compared against the affected criteria above. Do not include secrets or credentials.

AI-assisted, checked against the advisory. Informational, not a guarantee.

Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.

From vendor data
Mitigation available No clean upgrade yet — mitigate in the meantime
Mitigation

Apply vendor firmware patch when available; prior to patch, restrict network access to the device management interface and disable unauthenticated management protocols if feasible.

Fix this in Sonoma D12 Firmware Scoped from the published advisory
  • Consultation4.0 h
  • Implementation2.0 h
  • Testing8.0 h
  • Review / QA4.0 h
18.0 hours of engineering $3,080
Get help mitigating

An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $4,928.

Scan for this in your stack

Free · runs locally
dbcve dependency scanner

Check whether your project pulls in CVE-2025-60965 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.

References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.

Primary sources

Practitioner notes

Contributed

Peer-ranked notes from engineers who’ve handled CVE-2025-60965 in production — separate from our analysis above.

No notes yet

Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.

What this is

A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.

What belongs here
  • Verified mitigations, workarounds, and config changes
  • Version or environment caveats, and links to real fixes
  • No weaponised exploit code, or anything meant to cause harm
  • No spam, self-promotion, credentials, or personal data