CVE-2025-60964
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedOS Command Injection vulnerability in EndRun Technologies Sonoma D12 Network Time Server (GPS) F/W 6010-0071-000 Ver 4.00 allows attackers to execute arbitrary code, cause a denial of service, gain escalated privileges, gain sensitive information, and possibly other unspecified impacts.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · moderate confidenceOS Command Injection vulnerability in EndRun Technologies Sonoma D12 Network Time Server (GPS) firmware version 6010-0071-000 Ver 4.00 allows remote attackers to inject arbitrary OS commands through unsanitized input, potentially leading to arbitrary code execution, denial of service, privilege escalation, and information disclosure.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data= 6010-0071-000CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- High
- User interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Identify the device firmware versionAccess the Sonoma D12 management interface or check the device system information page to determine the installed firmware build number. Look for a version string matching 6010-0071-000.Affected if The displayed firmware version is exactly 6010-0071-000
-
Confirm the management interface is network accessibleVerify that the Sonoma D12 web interface or remote management service is reachable from the network. Check for open HTTP/HTTPS ports on the device IP address.Affected if The device management interface is exposed on the network and accepts external connections
-
Determine if authentication is enforced on input fieldsReview the device configuration pages that accept user input (such as network settings, NTP configuration, or admin panels). Attempt to identify if input sanitization or parameter binding is used.Affected if Input fields on the management interface accept special characters without validation or rejection
-
Check for exposed services accepting remote inputIdentify any services on the Sonoma D12 that accept remote user input, such as web forms, API endpoints, or configuration interfaces. Note which endpoints process input without visible sanitization.Affected if Remote-accessible services on the device accept user-supplied input without apparent sanitization controls
The device is affected if the firmware version is exactly 6010-0071-000 AND the management interface is network-accessible to accept the injection payload.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataApply vendor firmware patch when available; if no patch exists, implement network segmentation to limit exposure, disable unused services, and consider compensating controls such as WAF rules or IDS signatures for known injection patterns.
- Consultation8.0 h
- Implementation6.0 h
- Testing8.0 h
- Review / QA4.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $7,360.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2025-60964 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2025-60964 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data