CVE-2026-13084
Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedA null pointer dereference vulnerability in WatchGuard Fireware OS may allow a remote unauthenticated attacker to create a denial-of-service (DoS) condition by sending specially crafted IKEv2 messages. This vulnerability affects both the Mobile User VPN with IKEv2 and the Branch Office VPN using IKEv2 when configured with a dynamic gateway peer. This vulnerability affects Fireware OS 11.10.2 up to and including 11.12.4_Update1, 12.0 up to and including 12.12 and 2025.1 up to and including 2026.2
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceA null pointer dereference vulnerability exists in WatchGuard Fireware OS IKEv2 packet processing. When specially crafted IKEv2 messages are sent to affected VPN configurations (Mobile User VPN with IKEv2 or Branch Office VPN using IKEv2 with dynamic gateway peer), the device dereferences a null pointer, causing a denial-of-service condition.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data>= 12.5, < 12.5.19>= 11.0.0, < 11.12.4= 11.12.4>= 12.0, < 12.12.1>= 2025.1, < 2026.2.1CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Network
- Complexity
- Low
- Privileges
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Confirm WatchGuard Fireware OS installationAccess the Firebox management interface or run 'fireware -v' via CLI to identify the Fireware OS versionAffected if Device is not running WatchGuard Fireware OS (not applicable)
-
Compare installed Fireware OS versionNote the version number from the previous check and compare it to the vendor's official affected version list; if your version is lower than the first patched version, it may be vulnerableAffected if Running an unpatched Fireware OS version within the affected range (check vendor advisories for specific version numbers)
-
Verify Mobile User VPN with IKEv2 configurationIn Firebox System Manager or Policy Manager, navigate to VPN > Mobile User VPN and examine whether IKEv2 is enabled as the protocolAffected if Mobile User VPN is configured and IKEv2 protocol is selected/enabled
-
Verify Branch Office VPN with dynamic gateway peerIn Firebox System Manager or Policy Manager, navigate to VPN > Branch Office VPN and examine IKEv2 gateway configurations; check if the peer type is set to DynamicAffected if Branch Office VPN uses IKEv2 with a Dynamic gateway peer configured
The environment is affected if running an unpatched Fireware OS version AND either Mobile User VPN with IKEv2 or Branch Office VPN with IKEv2 dynamic gateway peer is actively configured.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor data11.12.412.5.1912.12.1
Apply vendor-provided patches when available. Until then, consider disabling IKEv2 dynamic gateway peer configurations or implementing network-level filtering to limit exposure to untrusted IKEv2 traffic sources.
- Consultation4.0 h
- Implementation2.0 h
- Testing4.0 h
- Review / QA2.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $3,392.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2026-13084 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2026-13084 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data