MEDIUM 5.5
CVE-2021-22781
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of U…
Ecostruxure Control Expert
15.0+
MEDIUM 5.5
CVE-2021-22782
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of U…
Ecostruxure Control Expert
15.0+
CRITICAL 9.8
CVE-2021-22763
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 an…
Powerlogic Pm5560 Firmware
2.7.8 / 10.7.3+
CRITICAL 9.8
CVE-2021-22765
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that co…
Powerlogic Egx100 Firmware
Mitigation only
CRITICAL 9.8
CVE-2021-22767
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that co…
Powerlogic Egx100 Firmware
Mitigation only
CRITICAL 9.8
CVE-2021-22768
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that co…
Powerlogic Egx100 Firmware
Mitigation only
HIGH 7.8
CVE-2021-22758
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22759
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code e…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22760
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22761
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22762
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that c…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.5
CVE-2021-22766
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that co…
Powerlogic Egx100 Firmware
Mitigation only
MEDIUM 5.3
CVE-2021-22764
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see securit…
Powerlogic Pm5560 Firmware
2.7.8 / 10.7.3+
HIGH 7.8
CVE-2021-22750
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote c…
Interactive Graphical Scada System
after 15.0.0.21041
HIGH 7.8
CVE-2021-22751
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of informatio…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22752
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote c…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22753
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote co…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22754
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote c…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22755
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of informatio…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22756
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information…
Interactive Graphical Scada System
after 15.0.0.21140
HIGH 7.8
CVE-2021-22757
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information…
Interactive Graphical Scada System
after 15.0.0.21140
MEDIUM 5.3
CVE-2021-22749
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that …
Modicon X80 Bmxnor0200h Rtu Firmware
Mitigation only
CRITICAL 9.8
CVE-2021-22737
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized acc…
Spacelynk Firmware
after 2.6.0
CRITICAL 9.8
CVE-2021-22738
Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unau…
Spacelynk Firmware
after 2.6.0
HIGH 7.5
CVE-2021-22736
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 a…
Spacelynk Firmware
after 2.6.0
HIGH 7.2
CVE-2021-22734
Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause rem…
Spacelynk Firmware
after 2.6.0
HIGH 7.2
CVE-2021-22735
Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remo…
Spacelynk Firmware
after 2.6.0
MEDIUM 6.7
CVE-2021-22741
Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all…
Clearscada
after 83.7742.1
MEDIUM 6.5
CVE-2021-22740
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when …
Spacelynk Firmware
after 2.6.0
MEDIUM 5.9
CVE-2021-22739
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when…
Spacelynk Firmware
after 2.6.0