Top technology
Linux 13140
Google 12525
Microsoft 12378
Apple 6692
Oracle 6673
Adobe 6383
Ibm 6286
Cisco 5751
Debian 3919
Mozilla 2886
Apache 2864
Redhat 2586
HIGH 8.2
CVE-2018-4851
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device c…
Siclock Tc400 Firmware
Mitigation only
MEDIUM 6.5
CVE-2018-4855
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client …
Siclock Tc400 Firmware
Mitigation only
HIGH 8.8
CVE-2018-11447
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF…
Scalance M875 Firmware
Mitigation only
HIGH 7.8
CVE-2018-11449
A vulnerability has been identified in SCALANCE M875 (All versions). An attacker with access to the local file system might obtain passwords for admi…
Scalance M875 Firmware
Mitigation only
HIGH 7.2
CVE-2018-4859
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), cou…
Scalance M875 Firmware
Mitigation only
HIGH 7.2
CVE-2018-4860
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), cou…
Scalance M875 Firmware
Mitigation only
CRITICAL 9.8
CVE-2017-12739EPSS 6%
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The in…
Sm 2556 Firmware
Mitigation only
MEDIUM 6.1
CVE-2017-12738
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The in…
Sm 2556 Firmware
Mitigation only
MEDIUM 5.3
CVE-2017-12737
An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The in…
Sm 2556 Firmware
Mitigation only
CRITICAL 9.8
CVE-2017-6869
A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user …
Viewport For Web Office Portal
Mitigation only
HIGH 7.4
CVE-2017-6873
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in…
Ozw772 Firmware
Mitigation only
MEDIUM 6.5
CVE-2017-6872
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to …
Ozw772 Firmware
Mitigation only
MEDIUM 6.5
CVE-2017-6865
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET…
Pcs 7
Mitigation only
HIGH 7.4
CVE-2017-2685
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (ex…
Sinumerik Integrate Access Mymachine\/ethernet
Mitigation only
HIGH 7.5
CVE-2016-9158
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS varia…
Simatic S7 300 Cpu Firmware
Mitigation only
MEDIUM 5.9
CVE-2016-9159
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS varia…
Simatic S7 300 Cpu Firmware
Mitigation only
HIGH 8.8
CVE-2016-8673
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl…
Simatic S7 300 Cpu Firmware
Mitigation only
MEDIUM 5.3
CVE-2016-8672
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl…
Simatic Cp 343 1 Firmware
Mitigation only
HIGH 8.8
CVE-2016-7114
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP …
En100 Ethernet Module Firmware
Mitigation only
HIGH 7.5
CVE-2016-7113
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP …
En100 Ethernet Module Firmware
Mitigation only
HIGH 7.8
CVE-2016-6486
Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors.
Sinema Server
Mitigation only
HIGH 7.5
CVE-2016-5744
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.
Simatic Wincc
Mitigation only
HIGH 7.5
CVE-2016-3949
Siemens SIMATIC S7-300 Profinet-enabled CPU devices with firmware before 3.2.12 and SIMATIC S7-300 Profinet-disabled CPU devices with firmware before…
Simatic S7 300 With Profitnet Support Firmware
Mitigation only
MEDIUM 5.3
CVE-2016-4785
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP …
Siprotec Firmware
Mitigation only
MEDIUM 5.3
CVE-2016-4784
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP …
Siprotec Firmware
Mitigation only
MEDIUM 5.3
CVE-2016-3963EPSS 9%
Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443.
Scalance S613
No fix yet
MEDIUM 5.3
CVE-2016-2201
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102.
Simatic S7 1500 Cpu Firmware
Mitigation only
HIGH 7.5
CVE-2015-2177EPSS 35%
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 1…
Simatic S7 300 Cpu Firmware
No fix yet
MEDIUM 5.0
CVE-2015-1358
The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) bef…
Wincc
Mitigation only
HIGH 10.0
CVE-2015-1449
Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware b…
Ruggedcom Firmware
Mitigation only