Official description Straight from the sourceThe vendor's or NVD's own wording, published unedited. Authoritative, but often terse — it says what broke, rarely what to do.
NVD · uneditedMultiple untrusted search path vulnerabilities in the installer in Synology Cloud Station Drive before 4.2.5-4396 on Windows allow local attackers to execute arbitrary code and conduct DLL hijacking attacks via a Trojan horse (1) shfolder.dll, (2) ntmarta.dll, (3) secur32.dll or (4) dwmapi.dll file in the current working directory.
Technical summary Written by usOur analysis, written from the advisory, the CVSS vector and the affected-version data. It adds context the advisory leaves out, and never invents facts that are not in the source.
dbcve analysis · high confidenceSynology Cloud Station Drive installer before version 4.2.5-4396 on Windows is vulnerable to DLL hijacking. The installer loads DLLs from the current working directory instead of secure system paths, allowing a local attacker to place malicious DLLs (shfolder.dll, ntmarta.dll, secur32.dll, dwmapi.dll) that get executed with the installer's privileges.
Verify against the referenced sources before acting — the references below are authoritative for this CVE, this summary is not.
Affected products & versions What the vendor confirmedThe version ranges the vendor confirmed as vulnerable. If your version sits inside a range here, treat yourself as exposed until you have upgraded.
NVD · CPE data<= 4.2.4-4393CVSS breakdown How the score is builtThe industry scoring standard. It rates how the flaw is reached, what it takes to exploit, and what an attacker gains — the score is derived from those, not the other way round.
From the vector- Attack vector
- Local
- Complexity
- Low
- Privileges
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Am I affected? How to checkSteps we derive from the advisory and the affected-version data, so you can decide whether this CVE reaches your setup. They are a guide, not a scan — your own configuration is the authority.
dbcve checksWork through these to decide whether this CVE applies to you.
-
Check installed Synology Cloud Station Drive versionOpen Windows Control Panel > Programs and Features, or check the version in the application installation directory. Alternatively, right-click the installed executable and view Properties > Details to find the File Version.Affected if The installed version is 4.2.4-4393 or earlier (any version <= 4.2.4-4393).
-
Verify if the vulnerable installer was usedReview installation records or logs to determine which installer version was used to set up the current installation. Check the original installer file if retained, or look for installation logs in temp directories.Affected if The installer version used was 4.2.4-4393 or earlier.
-
Confirm the product is Cloud Station Drive (not Server)Verify the exact product name in Programs and Features matches 'Synology Cloud Station Drive'. This vulnerability affects only the Drive client, not other Synology products.Affected if The product is Synology Cloud Station Drive and the version is in the affected range.
A system is affected if Synology Cloud Station Drive version 4.2.4-4393 or earlier is currently installed, or if that version of the installer was previously used on the system.
Generated from the published advisory. Verify against your own configuration.
Remediation Closing itWhat it takes to close this. Where a vendor fix exists we point at it; where none exists we say so plainly, and can build one. Effort estimates are scoped from the advisory, not from your codebase.
From vendor dataUpdate Synology Cloud Station Drive to version 4.2.5-4396 or later. Additionally, run the installer from a trusted directory and avoid placing the installer in writable locations where attackers could place malicious DLLs.
- Consultation2.0 h
- Implementation1.0 h
- Testing2.0 h
- Review / QA1.0 h
An estimate, not a bill — we confirm scope with you before any work starts. Need it this week? Rush from $1,696.
Scan for this in your stack
Free · runs locallyCheck whether your project pulls in CVE-2017-11158 — or any other known-vulnerable package — straight from your lock files. Free and open source; it runs locally and uploads nothing.
References Go to the primary sourcePrimary sources — vendor advisories, patches and trackers. Where our summary and a reference disagree, the reference wins.
Primary sourcesPractitioner notes
ContributedPeer-ranked notes from engineers who’ve handled CVE-2017-11158 in production — separate from our analysis above.
The advisory tells you what broke. It rarely tells you what actually worked. If you’ve dealt with this one, that detail is what the next engineer is searching for.
- The version that genuinely resolved it — not the one the vendor claimed
- A config change or rule that shut the vector down
- A gotcha in the upgrade path that cost you an afternoon
No notes yet
Be the first to add a field note for this CVE — a mitigation you’ve verified, a version caveat, or a link to a working fix. Sign in above to contribute.
A place for practitioners to share what actually worked: a mitigation you’ve tested, a configuration change, a version- or environment-specific caveat, or a link to a verified patch. The most useful notes rise to the top as peers upvote them, so the signal stays high.
- Verified mitigations, workarounds, and config changes
- Version or environment caveats, and links to real fixes
- No weaponised exploit code, or anything meant to cause harm
- No spam, self-promotion, credentials, or personal data