CVE-2021-26262
Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
Mri 3t Firmware
6.0.0+
HIGH 8.8
CVE-2021-39375
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the WAdvancedFilter/getDimensionItemsByCode FilterValue paramet…
Tasy Electronic Medical Record
No fix yet
HIGH 8.8
CVE-2021-39376
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_U…
Tasy Electronic Medical Record
No fix yet
MEDIUM 6.5
CVE-2020-27298
Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), V…
Coronary Tools
Mitigation only
HIGH 7.5
CVE-2018-7580
Philips Hue is vulnerable to a Denial of Service attack. Sending a SYN flood on port tcp/80 will freeze Philips Hue's hub and it will stop responding…
Hue Firmware
No fix yet
HIGH 7.1
CVE-2020-16247
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
exposes a resource to the wrong control sphere, providing unintended actors wi…
Clinical Collaboration Platform
after 12.2.1
MEDIUM 6.5
CVE-2020-16200
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not properly control the allocation and maintenance of a limited
resource…
Clinical Collaboration Platform
after 12.2.1
MEDIUM 6.3
CVE-2020-16198
When an attacker claims to have a given identity,
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not prove or insufficie…
Clinical Collaboration Platform
after 12.2.1
MEDIUM 6.8
CVE-2020-16212
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended …
Patient Information Center Ix
Mitigation only
MEDIUM 6.5
CVE-2020-16216
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750,
MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior,
the pr…
Patient Information Center Ix
Mitigation only
MEDIUM 6.5
CVE-2020-16224
In Patient Information Center iX (PICiX) Versions C.02, C.03, the
software parses a formatted message or structure but does not handle or
incorrect…
Patient Information Center Ix
Mitigation only
HIGH 8.8
CVE-2020-16222
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and
PerformanceBridge Focal Point Version A.01, when an actor claims to have
a g…
Patient Information Center Ix
No fix yet
MEDIUM 6.4
CVE-2020-16228
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX4…
Patient Information Center Ix
Mitigation only
MEDIUM 5.0
CVE-2020-16214
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the
software saves user-provided information into a comma-separated value
(CSV)…
Patient Information Center Ix
Mitigation only
MEDIUM 5.3
CVE-2020-14518
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.
Dreammapper
after 2.24
HIGH 7.3
CVE-2020-7360
An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an a…
Smartcontrol
after 4.3.15
HIGH 7.9
CVE-2020-6007
Philips Hue Bridge model 2.X prior to and including version 1935144020 contains a Heap-based Buffer Overflow when handling a long ZCL string during t…
Hue Bridge V2 Firmware
after 1935144020
MEDIUM 6.5
CVE-2019-18263
An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016…
Veradius Unity Firmware
Mitigation only
MEDIUM 6.5
CVE-2019-18241
In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the a…
Intellibridge Ec40 Firmware
Mitigation only
HIGH 7.5
CVE-2019-18980
On Signify Philips Taolight Smart Wi-Fi Wiz Connected LED Bulb 9290022656 devices, an unprotected API lets remote users control the bulb's operation.…
Taolight Smart Wi Fi Wiz Connected Led Bulb 9290022656 Firmware
No fix yet
MEDIUM 5.3
CVE-2019-13557
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access …
Tasy Emr
after 3.02.1757
MEDIUM 6.8
CVE-2019-13546
In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthoriz…
Intellispace Perinatal
Mitigation only
HIGH 7.2
CVE-2019-13530
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Ver…
Intellivue Mp Monitors Mp20 Mp90 Firmware
Mitigation only
HIGH 7.2
CVE-2019-13534
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Ver…
Intellivue Mp Monitors Mp20 Mp90 Firmware
Mitigation only
MEDIUM 5.4
CVE-2019-6562
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in outpu…
Tasy Emr
after 3.02.1744
HIGH 8.8
CVE-2018-17906
Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within …
Intellispace Pacs
No fix yet
CRITICAL 9.8
CVE-2018-8856
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption o…
E Alert Firmware
Mitigation only
HIGH 7.5
CVE-2018-8854
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested …
E Alert Firmware
No fix yet
CRITICAL 9.8
CVE-2018-8850
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the i…
E Alert Firmware
Mitigation only
HIGH 8.8
CVE-2018-8852
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the softw…
E Alert Firmware
Mitigation only