HIGH 7.8
CVE-2014-9197
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access con…
Etg3000 Factorycast Hmi Gateway Firmware
Patch available
HIGH 10.0
CVE-2014-9190EPSS 6%
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrar…
Wonderware Intouch Access Anywhere Server
Mitigation only
HIGH 10.0
CVE-2014-8511
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via …
Proclima
after 6.0.1
HIGH 10.0
CVE-2014-0754EPSS 9%
Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before…
Stbnic2212 Firmware
Patch available
HIGH 7.8
CVE-2014-0789
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and…
Opc Factory Server Tlxcdlfofs
after 3.35
HIGH 9.3
CVE-2013-0662EPSS 22%
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute …
Concept
after 14.0
MEDIUM 6.9
CVE-2014-0774
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLU…
Ofs Test Client Tlxcdlfofs33
Mitigation only
MEDIUM 5.9
CVE-2014-0759
Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges v…
Floating License Manager
Mitigation only
HIGH 7.8
CVE-2013-2824
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare Pow…
Citectscada
Patch available
MEDIUM 5.0
CVE-2013-6143
The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of ser…
Telvent Sage 3030 Firmware
Mitigation only
HIGH 9.3
CVE-2013-2782
Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different cust…
Tburjr900
Mitigation only
MEDIUM 6.9
CVE-2013-2796
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read …
Citectscada
after 7.20
MEDIUM 6.6
CVE-2013-0687
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify …
Micom S1 Studio
Mitigation only
HIGH 10.0
CVE-2013-2762
The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remot…
Magelis Xbt Hmi
Mitigation only
HIGH 8.5
CVE-2013-0664
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows re…
Modicon Quantum Plc
Mitigation only
MEDIUM 5.0
CVE-2013-2763
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: th…
Modicon M340 Bmx Noc 0401 Firmware
Mitigation only
MEDIUM 6.8
CVE-2013-0663EPSS 6%
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0…
Modicon Quantum Plc
No fix yet
HIGH 10.0
CVE-2013-0658EPSS 22%
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbit…
Accutech Manager
after 2.00.1
HIGH 10.0
CVE-2013-0657EPSS 21%
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitra…
Interactive Graphical Scada System
after 10.0
HIGH 9.3
CVE-2013-0655
The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in…
Software Update Utility
Mitigation only
CRITICAL 9.8
CVE-2012-0931
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a d…
Modicon Quantum Plc
Mitigation only
HIGH 7.5
CVE-2012-0929
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the…
Modicon Quantum Plc
Mitigation only
MEDIUM 6.1
CVE-2012-0930
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via…
Modicon Quantum Plc
Mitigation only
HIGH 10.0
CVE-2011-4860
The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates th…
Quantum Ethernet Module 140noe77100
after 5.0
HIGH 10.0
CVE-2011-4861
The modbus_125_handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) allows re…
Quantum Ethernet Module 140noe77100
after 5.0
HIGH 10.0
CVE-2011-4859
The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the…
Quantum Ethernet Module 140cpu65150
after 5.0
HIGH 9.3
CVE-2011-4034EPSS 13%
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earl…
Vijeo Historian
after 4.30
MEDIUM 5.0
CVE-2011-4036
Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.…
Vijeo Historian
after 4.30
HIGH 7.2
CVE-2011-3330
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect …
Monitor Pro